ZERO CLAMP FOR BZO 3 AsXs
P4 – NILED

Technical informations

To connect the lighting lamp to the neutral wire of an insulated line. For use in the internal power line connection.

Installation recommendations

  • Use a socket or ring wrench to mount the clamp.
  • Push the branch hose all the way into the sealing cap.
  • Tighten the screw to break the head. Breaking the screw head guarantees a proper connection.
  • When removing the clamp, loosen the screw with a wrench.
  • The disassembled clamp is not reusable.

Advantages

  • Ensured tightness of the connection (6kV test under water
  • Installation without a torque wrench - Correct clamping torque ensured by the self-tapping screw head
  • Clamps made of materials resistant to corrosion and UV radiation
  • Terminals designed for work on AL, Cu cables

Technical data

  • Main cable Al: 6-95 mm2
  • Branch cable: 1.5-6 mm2
  • Tightening torque 6 (breaking the screw head)
  • Key size 10 10

Notes: double-piercing

© 2021 SINTUR Spółka z o.o.