ZERO CLAMP FOR BZO 3 AsXs
P4 – NILED
Technical informations
To connect the lighting lamp to the neutral wire of an insulated line. For use in the internal power line connection.
Installation recommendations
- Use a socket or ring wrench to mount the clamp.
- Push the branch hose all the way into the sealing cap.
- Tighten the screw to break the head. Breaking the screw head guarantees a proper connection.
- When removing the clamp, loosen the screw with a wrench.
- The disassembled clamp is not reusable.
Advantages
- Ensured tightness of the connection (6kV test under water
- Installation without a torque wrench - Correct clamping torque ensured by the self-tapping screw head
- Clamps made of materials resistant to corrosion and UV radiation
- Terminals designed for work on AL, Cu cables
Technical data
- Main cable Al: 6-95 mm2
- Branch cable: 1.5-6 mm2
- Tightening torque 6 (breaking the screw head)
- Key size 10 10
Notes: double-piercing